It should be noticed that ANSI is no longer used in practice in the United States. For arched roof resting on an elevated structure like enclosure walls. Pressure coefficients for arched roof springing from ground surface that can be used for barrel vault design. A detailed comparison of the available codes concerning wind loads has revealed quite a large difference between the practices adopted by various countries. The wind loads usually represent a significant proportion of the overall forces acting on barrel vaults and domes. Ponding results when water on a double-layer grid flat roof accumulates faster than it runs off, thus causing excessive load on the roof. Rain load may be important in the tropical climate especially if the drainage provisions are insufficient. Detailed methods for the determination of these coefficients are given in the annexes of the Standard. It varies between 1.333, for slippery, unobstructed surfaces, to 1.0, for other surfaces. The surface material coefficient, Cm, defines a reduction of the snow load on roofs made of surface material with low surface roughness. For such cases Ct may take values less than unity. The thermal coefficient, Ct, is introduced to account for the reduction of snow load on roofs with high thermal transmittance, in particular glass-covered roofs, from melting caused by heat loss through the roof. However, the designer should always assess whether calm weather conditions (i.e., Ce = 10) during the snowfall season might yield more severe conditions for the structure. For regions where there are not sufficient sinter climatological data available, it is recommended to set Ce = 0.8. The exposure coefficient, Ce, defines the balanced load on a flat horizontal roof of a cold building as a fraction of the characteristic load on the ground. Snow loads on simple curved roofs and domes. Where s0 is the characteristic snow load on the ground (in kN/m2), mb is the slope reduction coefficient, md is the drift load coefficient, Ce is the exposure reduction coefficient, Ct is the thermal reduction coefficient, and Cm is the surface material coefficient. The snow loads can be calculated by the following formulas: The drift load may likewise be given by the corresponding arch drift load along the plan diameter being parallel to the wind direction multiplied by a reduction factor (1-a/r) where r is the plan radius and a is the horizontal distance from the wind direction diameter to any parallel plan chord. For domes of circular plan form, an axially symmetrical balanced load may be given as the corresponding balanced arch load. The intensity of snow load as specified in Bases for Design of Structures: Determination of Snow Loads on Roofs is reproduced as Figure 24.21. It was recommended by ISO for the determination of snow loads on simple curved roofs, pointed arches, and domes. Often more than one assumed distribution of snow load is considered. Each space frame is designed with uniformly distributed snow load and further allowed for drifting depending on the shape and slope of the structure. Live load is specified by the local building code and compared with the possible snow or rain load the larger one should be used as the design load. Where q w indicates all dead and live loads acting on double-layer grid except its self-weight (in kN/m2) L is the shorter span (in m) and Z is a coefficient, 1.0 for steel tubes and 1.2 for mill sections. An empirical formula is suggested to estimate the dead weight g of double-layer grids: The weight of various accessories - cladding, supported lighting, heat and ventilation equipment - and the weight of space frame comprise the total dead load. The design dead load is established on the basis of the actual loads that may be expected to act on the structure of constant magnitude. Intersection and combination of cylindrical shells.Ĭombination of cylindrical and spherical shells.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |